View Record

degree_chart

Degree of dilution Graph

The degree of dilution as shown in tha graph is based on:

  1. the calculated release characteristic (and applied safety factor with the 2020 version of the standard) and;
  2. the air velocity around the source of release; 

    and for indoor situations also:
     
  3. on the background concentration in relation to the critical concentration.

The Standard gives the following remarks with this figure:

  • The graph is based on an initial background concentration that is negligible.
  • Graph C.1 is not intended for guidance when considering releases from large pools.
  • Extrapolation of the curves beyond the chart area shown in Figure C.1 should not be undertaken due to other factors that will affect the assessment beyond the limits indicated.

Gráfico de grado de dilución

El grado de dilución mostrado en este gráfico se basa en:

  1. la característica de liberación calculada (y el factor de seguridad aplicado con la versión 2020 de la norma) y;
  2. la velocidad del aire alrededor de la fuente de liberación; 

    y para situaciones en interiores también:
     
  3. la concentración de fondo en relación con la concentración crítica.

La Norma hace las siguientes observaciones con esta figura:

  • El gráfico se basa en una concentración de fondo inicial que es despreciable.
  • El gráfico C.1 no pretende servir de orientación cuando se consideren liberaciones procedentes de grandes piscinas.
  • No debe realizarse la extrapolación de las curvas más allá del área del gráfico que se muestra en la figura C.1 debido a otros factores que afectarán a la evaluación más allá de los límites indicados.
.