availability_ventilation
Availability of the ventilation
The availability of the ventilation must be classified. IEC 60079-10-1 specifies 3 levels:
Different types of ventilation require different approaches for assessing their availability, e.g. availability of natural ventilation indoors shall never be considered as good because it depends heavily upon ambient conditions, i.e. outdoor temperature and wind.
The availability of natural ventilation can be fair but never good! The uncertainty due to whether conditions is too high, for the availability of natural ventilation, being "good"
See C.3.7.1 of IEC 60079-10-1:2020 for more guidance.
Tip:
Disponibilidad de la ventilación
La disponibilidad de la ventilación debe clasificarse. La norma IEC 60079-10-1 especifica 3 niveles:
Los diferentes tipos de ventilación requieren diferentes enfoques para evaluar su disponibilidad, por ejemplo la disponibilidad de la ventilación natural en interiores nunca se considerará buena porque depende en gran medida de las condiciones ambientales, es decir, de la temperatura exterior y del viento.
La disponibilidad de la ventilación natural puede ser regular pero nunca buena! La incertidumbre debida a si las condiciones son demasiado altas, para que la disponibilidad de la ventilación natural sea "buena"
Véase C.3.7.1 de IEC 60079-10-1:2020 para más orientación.
Consejo: